Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 577
Filter
2.
Sci Rep ; 14(1): 8674, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622364

ABSTRACT

Distinguishing syngenetic from protogenetic inclusions in natural diamonds is one of the most debated issues in diamond research. Were the minerals that now reside in inclusions in diamonds born before the diamond that hosts them (protogenesis)? Or did they grow simultaneously and by the same reaction (syngenesis)? Once previously published data on periclase [(Mg,Fe)O] and magnesiochromite (MgCr2O4) inclusions in diamond have been re-analysed, we show that the main arguments reported so far to support syngenesis between diamond and its mineral inclusions, definitely failed. Hence: (a) the epitaxial relationships between diamond and its mineral inclusion should no longer be used to support syngenesis, because only detecting an epitaxy does not tell us which was the nucleation substrate (there are evidences that in case of epitaxy, the inclusion acts as a nucleation substrate); (b) the morphology of the inclusion should no longer be used as well, as inclusions could be protogenetic regardless their shapes. Finally, we advance the hypothesis that the majority of inclusions in diamonds are protogenetic, e.g., they are constituent of rocks in which diamonds were formed and not products of reactions during diamond growth.

3.
Endoscopy ; 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38626890

ABSTRACT

BACKGROUND AND STUDY AIMS: Endoscopic transmural drainage (ETD) using double pigtail stents (DPS) is a well-established treatment for walled-off pancreatic necrosis (WON). This study aimed to compare outcomes in patients undergoing ETD with DPS left indwelling versus those where stents were removed or migrated. PATIENTS AND METHODS: This retrospective, multicenter cohort study included patients with WON who underwent ETD using DPS between July 2001 and December 2019. The primary outcome was recurrence of a pancreatic fluid collection (PFC). Secondary outcomes were long term complications and recurrence-associated factors. Competing risk regression analysis considered DPS removal or migration as time-varying covariate. RESULTS: Among 320 patients (median age 58, 36% female), DPS were removed in 153 (47.8%), migrated spontaneously in 27 (8.4%), and remained indwelling in 140 (43.8%). PFC recurrence was observed in 57 patients (17.8%): after removal in 39 (25.5%), after migration in 4 (14.8%) and in patients with indwelling DPS in 14 patients (10%). In 25 patients (7.8%) drainage of recurrent PFC was indicated. Risk factors for recurrence were DPS removal or migration (HR: 3.45, 95%CI: 1.37-8.70) and presence of a disconnected pancreatic duct (HR: 3.45, 95%CI: 1.84-14.0). CONCLUSIONS: Among patients who undergo ETD of WON, leaving DPS in situ seems to lower the risk on recurrent fluid collections, without any long term DPS-related complications. These results suggest that DPS should not be routinely removed and can be safely left indwelling indefinitely.

4.
Fam Cancer ; 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38573399

ABSTRACT

Individuals at high risk of developing pancreatic ductal adenocarcinoma are eligible for surveillance within research programs. These programs employ periodic imaging in the form of magnetic resonance imaging/magnetic resonance cholangiopancreatography or endoscopic ultrasound for the detection of early cancer or high-grade precursor lesions. This narrative review discusses the role of endoscopic ultrasound within these surveillance programs. It details its overall strengths and limitations, yield, burden on patients, and how it compares to magnetic resonance imaging. Finally, recommendations are given when and how to incorporate endoscopic ultrasound in the surveillance of high-risk individuals.

5.
Genes (Basel) ; 15(4)2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38674415

ABSTRACT

Studies have revealed anthropometric discrepancies in girls with adolescent idiopathic scoliosis (AIS) compared to non-scoliotic subjects, such as a higher stature, lower weight, and lower body mass index. While the causes are still unknown, it was proposed that metabolic hormones could play a role in AIS pathophysiology. Our objectives were to evaluate the association of GLP1R A316T polymorphism in AIS susceptibility and to study its relationship with disease severity and progression. We performed a retrospective case-control association study with controls and AIS patients from an Italian and French Canadian cohort. The GLP1R rs10305492 polymorphism was genotyped in 1025 subjects (313 non-scoliotic controls and 712 AIS patients) using a validated TaqMan allelic discrimination assay. Associations were evaluated by odds ratio and 95% confidence intervals. In the AIS group, there was a higher frequency of the variant genotype A/G (4.2% vs. 1.3%, OR = 3.40, p = 0.016) and allele A (2.1% vs. 0.6%, OR = 3.35, p = 0.017) than controls. When the AIS group was stratified for severity (≤40° vs. >40°), progression of the disease (progressor vs. non-progressor), curve type, or body mass index, there was no statistically significant difference in the distribution of the polymorphism. Our results support that the GLP1R A316T polymorphism is associated with a higher risk of developing AIS, but without being associated with disease severity and progression.


Subject(s)
Glucagon-Like Peptide-1 Receptor , Polymorphism, Single Nucleotide , Scoliosis , Humans , Scoliosis/genetics , Female , Adolescent , Italy/epidemiology , Male , Glucagon-Like Peptide-1 Receptor/genetics , Case-Control Studies , Genetic Predisposition to Disease , Canada/epidemiology , Retrospective Studies , Child , Mutation
6.
Article in English | MEDLINE | ID: mdl-38583511
7.
World J Gastroenterol ; 30(8): 811-816, 2024 Feb 28.
Article in English | MEDLINE | ID: mdl-38516233

ABSTRACT

Endoscopic ultrasound (EUS) with fine needle aspiration or fine needle biopsy is the gold standard for sampling tissue to diagnose pancreatic cancer and autoimmune pancreatitis or to analyze cyst fluid. The most common reported adverse event of fine needle aspiration and/or fine needle biopsy is acute pancreatitis, which is likely induced by the same pathophysiological mechanisms as after endoscopic retrograde cholangiopancreatography (ERCP). According to the current European Society of Gastrointestinal Endoscopy guideline, nonsteroidal anti-inflammatory drugs are administered prior to ERCP as a scientifically proven treatment to reduce post-ERCP pancreatitis incidence rate. A single suppository of diclofenac or indomethacin prior to EUS guided tissue acquisition (TA) is harmless in healthy adults. Since it is associated with low costs and, most important, may prevent a dreadsome complication, we strongly recommend the administration of 100 mg diclofenac rectally prior to EUS-TA. We will explain this recommendation in more detail in this review as well as the risk and pathophysiology of post-EUS TA pancreatitis.


Subject(s)
Pancreatitis , Adult , Humans , Pancreatitis/epidemiology , Pancreatitis/etiology , Pancreatitis/prevention & control , Incidence , Diclofenac/therapeutic use , Acute Disease , Anti-Inflammatory Agents, Non-Steroidal/therapeutic use , Cholangiopancreatography, Endoscopic Retrograde/adverse effects , Ultrasonography, Interventional/adverse effects , Endoscopic Ultrasound-Guided Fine Needle Aspiration/adverse effects
8.
Endosc Int Open ; 12(3): E428-E434, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38504741

ABSTRACT

Background and study aims Reprocessing reusable endoscopes is challenging due to their non-sterilizable nature. Disinfection has been shown to have a significant risk of failure with serious consequences. Single-use endoscopes can eliminate contamination risk and reduce workflow delays caused by reprocessing. This study evaluated the clinical performance of single-use gastroscopes in patients undergoing esophagogastroduodenoscopy (EGD). Patients and methods In this case series, 60 patients underwent EGD using single-use gastroscopes, with 34 procedures in the endoscopy department and 26 in the intensive care unit. The primary outcome was successful completion of the intended EGD objective. Furthermore, certified endoscopists assessed device performance on a five-point Likert scale (ranging from 1-"much worse" to 5-"much better"), considering their experience with a reusable gastroscope. Results Successful completion of EGDs using only the single-use gastroscope was achieved in 58 of 60 cases (96.7%). In two cases, crossover to an ultra-slim endoscope was necessary to either reach the esophageal stenosis or to transverse the stenosis. Overall satisfaction was rated as comparable to reusable scopes in 51 of 56 cases (91.1%) and inferior in five cases (8.9%). The lower weight of the single-use gastroscope was rated as superior in 42 of 60 cases (70.0%). Drawbacks included reduced image quality (23 of 45 cases; 51.1%). Feedback included the absence of a freeze button, lens cleaning issues, and small image size. Conclusions Single-use gastroscopes exhibited a high EGD completion rate and effectiveness for various indications. Further research should focus on evaluating the implementation of single-use gastroscopes in a comprehensive context, considering clinical effectiveness, costs, and environmental impact.

9.
Lancet Gastroenterol Hepatol ; 9(4): 299-309, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38301673

ABSTRACT

BACKGROUND: Mesenteric artery stenting with a bare-metal stent is the current treatment for atherosclerotic chronic mesenteric ischaemia. Long-term patency of bare-metal stents is unsatisfactory due to in-stent intimal hyperplasia. Use of covered stents might improve long-term patency. We aimed to compare the patency of covered stents and bare-metal stents in patients with chronic mesenteric ischaemia. METHODS: We conducted a multicentre, patient-blinded and investigator-blinded, randomised controlled trial including patients with chronic mesenteric ischaemia undergoing mesenteric artery stenting. Six centres in the Netherlands participated in this study, including two national chronic mesenteric ischaemia expert centres. Patients aged 18 years or older were eligible for inclusion when an endovascular mesenteric artery revascularisation was scheduled and a consensus diagnosis of chronic mesenteric ischaemia was made by a multidisciplinary team of gastroenterologists, interventional radiologists, and vascular surgeons. Exclusion criteria were stenosis length of 25 mm or greater, stenosis caused by median arcuate ligament syndrome or vasculitis, contraindication for CT angiography, or previous target vessel revascularisation. Digital 1:1 block randomisation with block sizes of four or six and stratification by inclusion centre was used to allocate patients to undergo stenting with bare-metal stents or covered stents at the start of the procedure. Patients, physicians performing follow-up, investigators, and radiologists were masked to treatment allocation. Interventionalists performing the procedure were not masked. The primary study outcome was the primary patency of covered stents and bare-metal stents at 24 months of follow-up, evaluated in the modified intention-to-treat population, in which stents with missing data for the outcome were excluded. Loss of primary patency was defined as the performance of a re-intervention to preserve patency, or 75% or greater luminal surface area reduction of the target vessel. CT angiography was performed at 6 months, 12 months, and 24 months post intervention to assess patency. The study is registered with ClinicalTrials.gov (NCT02428582) and is complete. FINDINGS: Between April 6, 2015, and March 11, 2019, 158 eligible patients underwent mesenteric artery stenting procedures, of whom 94 patients (with 128 stents) provided consent and were included in the study. 47 patients (62 stents) were assigned to the covered stents group (median age 69·0 years [IQR 63·0-76·5], 28 [60%] female) and 47 patients (66 stents) were assigned to the bare-metal stents group (median age 70·0 years [63·5-76·5], 33 [70%] female). At 24 months, the primary patency of covered stents (42 [81%] of 52 stents) was superior to that of bare-metal stents (26 [49%] of 53; odds ratio [OR] 4·4 [95% CI 1·8-10·5]; p<0·0001). A procedure-related adverse event occurred in 17 (36%) of 47 patients in the covered stents group versus nine (19%) of 47 in the bare-metal stent group (OR 2·4 [95% CI 0·9-6·3]; p=0·065). Most adverse events were related to the access site, including haematoma (five [11%] in the covered stents group vs six [13%] in the bare-metal stents group), pseudoaneurysm (five [11%] vs two [4%]), radial artery thrombosis (one [2%] vs none), and intravascular closure device (none vs one [2%]). Six (13%) patients in the covered stent group versus one (2%) in the bare-metal stent group had procedure-related adverse events not related to the access site, including stent luxation (three [6%] vs none), major bleeding (two (4%) vs none), mesenteric artery perforation (one [2%] vs one [2%]), mesenteric artery dissection (one [2%] vs one [2%]), and death (one [2%] vs none). INTERPRETATION: The findings of this trial support the use of covered stents for mesenteric artery stenting in patients with chronic mesenteric ischaemia. FUNDING: Atrium Maquet Getinge Group.


Subject(s)
Atherosclerosis , Mesenteric Ischemia , Humans , Female , Aged , Male , Mesenteric Ischemia/surgery , Constriction, Pathologic/etiology , Stents/adverse effects , Mesenteric Arteries
10.
Eur Spine J ; 33(4): 1665-1674, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38407613

ABSTRACT

INTRODUCTION: Our objective was to assess abnormalities of the odontoid-hip axis (OD-HA) angle in a mild scoliotic population to determine whether screening for malalignment would help predict the distinction between progressive and stable adolescent idiopathic scoliosis (AIS) at early stage. MATERIALS AND METHODS: All patients (non-scoliotic and AIS) underwent a biplanar X-ray between 2013 and 2020. In AIS, inclusion criteria were Cobb angle between 10° and 25°; Risser sign lower than 3; age higher than 10 years; and no previous treatment. A 3D spine reconstruction was performed, and the OD-HA was computed automatically. A reference corridor for OD-HA values in non-scoliotic subjects was calculated as the range [5th-95th percentiles]. A severity index, helping to distinguish stable and progressive AIS, was calculated and weighted according to the OD-HA value. RESULTS: Eighty-three non-scoliotic and 205 AIS were included. The mean coronal and sagittal OD-HA angles in the non-scoliotic group were 0.2° and -2.5°, whereas in AIS values were 0.3° and -0.8°, respectively. For coronal and sagittal OD-HA, 27.5% and 26.8% of AIS were outside the reference corridor compared with 10.8% in non-scoliotic (OR = 3.1 and 3). Adding to the severity index a weighting factor based on coronal OD-HA, for thoracic scoliosis, improved the positive predictive value by 9% and the specificity by 13%. CONCLUSION: Analysis of OD-HA suggests that AIS patients are almost three times more likely to have malalignment compared with a non-scoliotic population. Furthermore, analysis of coronal OD-HA is promising to help the clinician distinguish between stable and progressive thoracic scoliosis.


Subject(s)
Kyphosis , Scoliosis , Humans , Adolescent , Child , Scoliosis/diagnostic imaging , Scoliosis/surgery , Longitudinal Studies , Kyphosis/diagnostic imaging , Cohort Studies , Radiography , Retrospective Studies
11.
Gastrointest Endosc ; 2024 Feb 13.
Article in English | MEDLINE | ID: mdl-38360118

ABSTRACT

BACKGROUND AND AIMS: Obtaining adequate tissue samples in subepithelial lesions (SELs) remains challenging. Several biopsy techniques are available, but a systematic review including all available techniques to obtain a histological diagnosis of SEL is lacking. The aim of this study is to evaluate the diagnostic yield and complication rates of endoscopic biopsies, endoscopic ultrasound guided-FNA and -FNB (EUS-FNA/B), and mucosal incision assisted biopsy (MIAB) for SELs in the upper gastro-intestinal tract. METHODS: A search strategy in multiple databases was performed. The primary outcome was diagnostic yield, defined as the percentage of procedures where histology was obtained and resulted in a definitive histopathological diagnosis. Secondary outcome measures included reported procedure-related adverse events which were classified according to the AGREE classification. RESULTS: A total of 94 original papers were included. Studies were classified per endoscopic technique to obtain histopathology. This resulted in 8 included studies for endoscopic biopsy methods, 55 studies for EUS-FNA, 33 studies for EUS-FNB and 26 studies for MIAB. Pooled rates for diagnostic yield were 40.6% (95% CI 30.8-51.2%) for endoscopic biopsy, 74.6% (95% CI 69.9-78.7%) for EUS-FNA, 84.2% (95% CI 80.7-87.2%) for EUS-FNB, 88.2% (95% CI 84.7-91.1%) for MIAB. Reported procedure-related complications graded AGREE II or higher were 2.8-3.9% for endoscopic biopsies, 1.0-4.5% for EUS-FNA, 0.9-7.7 % for EUS-FNB, 1.9-7.9% for MIAB. CONCLUSION: Based on the available evidence, MIAB and EUS-FNB seem to be most effective in terms of achieving a high diagnostic yield, with similar rates of adverse events.

12.
Gut ; 73(4): 613-621, 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-38182137

ABSTRACT

OBJECTIVE: Contaminated duodenoscopes caused several hospital outbreaks. Despite efforts to reduce contamination rates, 15% of patient-ready duodenoscopes are still contaminated with gastrointestinal microorganisms. This study aimed to provide an overview of duodenoscope contamination over time, identify risk factors and study the effects of implemented interventions. DESIGN: Duodenoscope culture sets between March 2015 and June 2022 at a Dutch tertiary care centre were analysed. Contamination was defined as (1) the presence of microorganisms of oral or gastrointestinal origin (MGO) or (2) any other microorganism with ≥20 colony-forming units/20 mL (AM20). A logistic mixed effects model was used to identify risk factors and assess the effect of interventions, such as using duodenoscopes with disposable caps, replacing automated endoscope reprocessors (AER) and conducting audits in the endoscopy department. RESULTS: A total of 404 culture sets were analysed. The yearly contamination rate with MGO showed great variation, ranging from 14.3% to 47.5%. Contamination with AM20 increased up to 94.7% by 2022. For both MGO and AM20, the biopsy and suction channels were the most frequently contaminated duodenoscope components. The studied interventions, including audits, AER replacement and implementation of duodenoscopes with disposable caps, did not show a clear association with contamination rates. CONCLUSION: Duodenoscope contamination remains a significant problem, with high contamination rates despite several interventions. Reprocessing the biopsy and suction channels is especially challenging. Changes in the design of reusable duodenoscopes, such as enabling sterilisation or easily replaceable channels, are necessary to facilitate effective duodenoscope reprocessing and to eliminate the risk of duodenoscope-associated infections.


Subject(s)
Cross Infection , Duodenoscopes , Humans , Cholangiopancreatography, Endoscopic Retrograde , Cross Infection/prevention & control , Cross Infection/epidemiology , Magnesium Oxide , Retrospective Studies , Tertiary Care Centers
13.
Gut ; 73(5): 787-796, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38267201

ABSTRACT

OBJECTIVE: To describe the long-term consequences of necrotising pancreatitis, including complications, the need for interventions and the quality of life. DESIGN: Long-term follow-up of a prospective multicentre cohort of 373 necrotising pancreatitis patients (2005-2008) was performed. Patients were prospectively evaluated and received questionnaires. Readmissions (ie, for recurrent or chronic pancreatitis), interventions, pancreatic insufficiency and quality of life were compared between initial treatment groups: conservative, endoscopic/percutaneous drainage alone and necrosectomy. Associations of patient and disease characteristics during index admission with outcomes during follow-up were assessed. RESULTS: During a median follow-up of 13.5 years (range 12-15.5 years), 97/373 patients (26%) were readmitted for recurrent pancreatitis. Endoscopic or percutaneous drainage was performed in 47/373 patients (13%), of whom 21/47 patients (45%) were initially treated conservatively. Pancreatic necrosectomy or pancreatic surgery was performed in 31/373 patients (8%), without differences between treatment groups. Endocrine insufficiency (126/373 patients; 34%) and exocrine insufficiency (90/373 patients; 38%), developed less often following conservative treatment (p<0.001 and p=0.016, respectively). Quality of life scores did not differ between groups. Pancreatic gland necrosis >50% during initial admission was associated with percutaneous/endoscopic drainage (OR 4.3 (95% CI 1.5 to 12.2)), pancreatic surgery (OR 3.2 (95% CI 1.1 to 9.5) and development of endocrine insufficiency (OR13.1 (95% CI 5.3 to 32.0) and exocrine insufficiency (OR6.1 (95% CI 2.4 to 15.5) during follow-up. CONCLUSION: Acute necrotising pancreatitis carries a substantial disease burden during long-term follow-up in terms of recurrent disease, the necessity for interventions and development of pancreatic insufficiency, even when treated conservatively during the index admission. Extensive (>50%) pancreatic parenchymal necrosis seems to be an important predictor of interventions and complications during follow-up.


Subject(s)
Exocrine Pancreatic Insufficiency , Pancreatitis, Acute Necrotizing , Pancreatitis, Chronic , Humans , Pancreatitis, Acute Necrotizing/complications , Pancreatitis, Acute Necrotizing/surgery , Follow-Up Studies , Quality of Life , Prospective Studies , Exocrine Pancreatic Insufficiency/etiology , Pancreatitis, Chronic/complications , Drainage/adverse effects , Necrosis , Treatment Outcome
14.
Clin Gastroenterol Hepatol ; 22(1): 62-71.e7, 2024 01.
Article in English | MEDLINE | ID: mdl-37031711

ABSTRACT

BACKGROUND AND AIMS: In high-risk individuals (HRIs), we aimed to assess the cumulative incidence of intraductal papillary mucinous neoplasms (IPMNs) and compare IPMN growth, neoplastic progression rate, and the value of growth as predictor for neoplastic progression to these in sporadic IPMNs. METHODS: We performed annual surveillance of Dutch HRIs, involving carriers of germline pathogenic variants (PVs) and PV-negative familial pancreatic cancer kindreds. HRIs with IPMNs were compared with Italian individuals without familial risk under surveillance for sporadic IPMNs. RESULTS: A total of 457 HRIs were followed for 48 (range 2-172) months; the estimated cumulative IPMN incidence was 46% (95% confidence interval, 28%-64%). In comparison with 442 control individuals, IPMNs in HRIs were more likely to grow ≥2.5 mm/y (31% vs 7%; P < .001) and develop worrisome features (32% vs 19%; P = .010). PV carriers with IPMNs more often displayed neoplastic progression (n = 3 [11%] vs n = 6 [1%]; P = .011), while familial pancreatic cancer kindreds did not (n = 0 [0%]; P = 1.000). The malignancy risk in a PV carrier with an IPMN was 23% for growth rates ≥2.5 mm/y (n = 13), 30% for ≥5 mm/y (n = 10), and 60% for ≥10 mm/y (n = 5). CONCLUSIONS: The cumulative incidence of IPMNs in HRIs is higher than previously reported in the general population. Compared with sporadic IPMNs, they have an increased growth rate. PV carriers with IPMNs are suggested to be at a higher malignancy risk. Intensive follow-up should be considered for PV carriers with an IPMN growing ≥2.5 mm/y, and surgical resection for those growing ≥5 mm/y.


Subject(s)
Adenocarcinoma, Mucinous , Carcinoma, Pancreatic Ductal , Pancreatic Intraductal Neoplasms , Pancreatic Neoplasms , Humans , Incidence , Carcinoma, Pancreatic Ductal/epidemiology , Carcinoma, Pancreatic Ductal/genetics , Carcinoma, Pancreatic Ductal/pathology , Pancreatic Intraductal Neoplasms/epidemiology , Pancreatic Intraductal Neoplasms/genetics , Pancreatic Intraductal Neoplasms/pathology , Pancreatic Neoplasms/pathology , Adenocarcinoma, Mucinous/epidemiology , Adenocarcinoma, Mucinous/genetics , Adenocarcinoma, Mucinous/pathology , Retrospective Studies
15.
Am J Gastroenterol ; 119(4): 671-681, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-37934190

ABSTRACT

INTRODUCTION: The study aimed to develop international consensus recommendations on the safe use of lumen-apposing metal stents (LAMSs) for on- and off-label indications. METHODS: Based on the available literature, statements were formulated and grouped into the following categories: general safety measures, peripancreatic fluid collections, endoscopic ultrasound (EUS)-biliary drainage, EUS-gallbladder drainage, EUS-gastroenterostomy, and gastric access temporary for endoscopy. The evidence level of each statement was determined using the Grading of Recommendations Assessment, Development, and Evaluation methodology.International LAMS experts were invited to participate in a modified Delphi process. When no 80% consensus was reached, the statement was modified based on expert feedback. Statements were rejected if no consensus was reached after the third Delphi round. RESULTS: Fifty-six (93.3%) of 60 formulated statements were accepted, of which 35 (58.3%) in the first round. Consensus was reached on the optimal learning path, preprocedural imaging, the need for airway protection and essential safety measures during the procedure, such as the use of Doppler, and measurement of the distance between the gastrointestinal lumen and the target structure. Specific consensus recommendations were generated for the different LAMS indications, covering, among others, careful patient selection, the preferred size of the LAMS, the need for antibiotics, the preferred anatomic location of the LAMS, the need for coaxial pigtail placement, and the appropriate management of LAMS-related adverse events. DISCUSSION: Through a modified international Delphi process, we developed general and indication-specific experience- and evidence-based recommendations on the safe use of LAMS.


Subject(s)
Endosonography , Off-Label Use , Humans , Consensus , Retrospective Studies , Stents/adverse effects , Endoscopy, Gastrointestinal , Drainage/methods
16.
Gastrointest Endosc ; 99(4): 587-595.e1, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37951279

ABSTRACT

BACKGROUND AND AIMS: Ampullary lesions (ALs) of the minor duodenal papilla are extremely rare. Endoscopic papillectomy (EP) is a routinely used treatment for AL of the major duodenal papilla, but the role of EP for minor AL has not been accurately studied. METHODS: We identified 20 patients with ALs of minor duodenal papilla in the multicentric database from the Endoscopic Papillectomy vs Surgical Ampullectomy vs Pancreatitcoduodenectomy for Ampullary Neoplasm study, which included 1422 EPs. We used propensity score matching (nearest-neighbor method) to match these cases with ALs of the major duodenal papilla based on age, sex, histologic subtype, and size of the lesion in a 1:2 ratio. Cohorts were compared by means of chi-square or Fisher exact test as well as Mann-Whitney U test. RESULTS: Propensity score-based matching identified a cohort of 60 (minor papilla 20, major papilla 40) patients with similar baseline characteristics. The most common histologic subtype of lesions of minor papilla was an ampullary adenoma in 12 patients (3 low-grade dysplasia and 9 high-grade dysplasia). Five patients revealed nonneoplastic lesions. Invasive cancer (T1a), adenomyoma, and neuroendocrine neoplasia were each found in 1 case. The rate of complete resection, en-bloc resection, and recurrences were similar between the groups. There were no severe adverse events after EP of lesions of minor papilla. One patient had delayed bleeding that could be treated by endoscopic hemostasis, and 2 patients showed a recurrence in surveillance endoscopy after a median follow-up of 21 months (interquartile range, 12-50 months). CONCLUSIONS: EP is safe and effective in ALs of the minor duodenal papilla. Such lesions could be managed according to guidelines for EP of major duodenal papilla.


Subject(s)
Ampulla of Vater , Common Bile Duct Neoplasms , Duodenal Neoplasms , Pancreatic Neoplasms , Humans , Treatment Outcome , Ampulla of Vater/surgery , Ampulla of Vater/pathology , Endoscopy, Gastrointestinal , Pancreatic Ducts/pathology , Pancreatic Neoplasms/pathology , Duodenal Neoplasms/pathology , Common Bile Duct Neoplasms/surgery , Common Bile Duct Neoplasms/pathology , Retrospective Studies
17.
Endoscopy ; 56(3): 198-204, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37848074

ABSTRACT

BACKGROUND: Current duodenoscope reprocessing protocols are insufficient to prevent contamination and require adaptations to prevent endoscopy-associated infections (EAIs). This study aimed to investigate the effect of a new endoscope cleaning brush on the contamination rate of ready-to-use duodenoscopes. METHODS: This retrospective before-and-after intervention study collected duodenoscope surveillance culture results from March 2018 to June 2022. Contamination was defined as ≥1 colony-forming unit of a microorganism of gut or oral origin (MGO). In December 2020, an endoscope cleaning brush with a sweeper design was introduced as an intervention in the manual cleaning of duodenoscopes. A logistic mixed-effects model was used to study the effects of this intervention. RESULTS: Data were collected from 176 culture sets before the new brush's introduction and 81 culture sets afterwards. Pre-introduction, culture sets positive with an MGO comprised 45.5% (95%CI 38.3%-52.8%; 80/176), decreasing to 17.3% (95%CI 10.6%-26.9%; 14/81) after implementation of the new brush. Compared with the former brush, duodenoscopes cleaned with the new brush had lower odds of contamination with MGOs (adjusted odds ratio 0.25, 95%CI 0.11-0.58; P=0.001) CONCLUSIONS: Use of the new brush in manual cleaning reduced contamination with MGOs and is expected to prevent EAIs. These findings should be confirmed in future prospective randomized studies.


Subject(s)
Duodenoscopes , Magnesium Oxide , Humans , Retrospective Studies , Disinfection/methods , Equipment Contamination/prevention & control , Endoscopy, Gastrointestinal
18.
Ann Surg ; 279(4): 671-678, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-37450701

ABSTRACT

OBJECTIVE: To compare the long-term outcomes of immediate drainage versus the postponed-drainage approach in patients with infected necrotizing pancreatitis. BACKGROUND: In the randomized POINTER trial, patients assigned to the postponed-drainage approach using antibiotic treatment required fewer interventions, as compared with immediate drainage, and over a third were treated without any intervention. METHODS: Clinical data of those patients alive after the initial 6-month follow-up were re-evaluated. The primary outcome was a composite of death and major complications. RESULTS: Out of 104 patients, 88 were re-evaluated with a median follow-up of 51 months. After the initial 6-month follow-up, the primary outcome occurred in 7 of 47 patients (15%) in the immediate-drainage group and 7 of 41 patients (17%) in the postponed-drainage group (RR 0.87, 95% CI 0.33-2.28; P =0.78). Additional drainage procedures were performed in 7 patients (15%) versus 3 patients (7%) (RR 2.03; 95% CI 0.56-7.37; P =0.34). The median number of additional interventions was 0 (IQR 0-0) in both groups ( P =0.028). In the total follow-up, the median number of interventions was higher in the immediate-drainage group than in the postponed-drainage group (4 vs. 1, P =0.001). Eventually, 14 of 15 patients (93%) in the postponed-drainage group who were successfully treated in the initial 6-month follow-up with antibiotics and without any intervention remained without intervention. At the end of follow-up, pancreatic function and quality of life were similar. CONCLUSIONS: Also, during long-term follow-up, a postponed-drainage approach using antibiotics in patients with infected necrotizing pancreatitis results in fewer interventions as compared with immediate drainage and should therefore be the preferred approach. TRIAL REGISTRATION: ISRCTN33682933.


Subject(s)
Pancreatitis, Acute Necrotizing , Quality of Life , Humans , Treatment Outcome , Pancreatitis, Acute Necrotizing/complications , Pancreatitis, Acute Necrotizing/surgery , Anti-Bacterial Agents/therapeutic use , Drainage/methods
19.
Gastrointest Endosc ; 99(4): 548-556, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37890597

ABSTRACT

BACKGROUND AND AIMS: For a highly selected group of patients with unresectable perihilar cholangiocarcinoma (pCCA), liver transplantation (LT) is a treatment option. The Dutch screening protocol comprises nonregional lymph node (LN) assessment by EUS, and whenever LN metastases are identified, further LT screening is precluded. The aim of this study is to investigate the yield of EUS in patients with pCCA who are potentially eligible for LT. METHODS: In this retrospective, nationwide cohort study, all consecutive patients with suspected unresectable pCCA who underwent EUS in the screening protocol for LT were included from 2011 to 2021. During EUS, sampling of a "suspicious" nonregional LN was performed based on the endoscopist's discretion. The primary outcome was the added value of EUS, defined as the number of patients who were precluded from further screening because of malignant LNs. RESULTS: A total of 75 patients were included in whom 84 EUS procedures were performed, with EUS-guided tissue acquisition confirming malignancy in LNs in 3 of 75 (4%) patients. In the 43 who underwent surgical staging according to the protocol, nonregional LNs with malignancy were identified in 6 (14%) patients. Positive regional LNs were found in 7 patients in post-LT-resected specimens. CONCLUSIONS: Our current EUS screening for the detection of malignant LNs in patients with pCCA eligible for LT shows a limited but clinically important yield. EUS with systematic screening of all LN stations, both regional and nonregional, and the sampling of suspicious lymph nodes according to defined and set criteria could potentially increase this yield.


Subject(s)
Bile Duct Neoplasms , Cholangiocarcinoma , Klatskin Tumor , Liver Transplantation , Humans , Cohort Studies , Retrospective Studies , Klatskin Tumor/diagnostic imaging , Klatskin Tumor/surgery , Klatskin Tumor/pathology , Endosonography/methods , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Cholangiocarcinoma/diagnostic imaging , Cholangiocarcinoma/surgery , Cholangiocarcinoma/pathology , Bile Ducts, Intrahepatic/diagnostic imaging , Bile Ducts, Intrahepatic/surgery , Bile Duct Neoplasms/diagnostic imaging , Bile Duct Neoplasms/surgery , Bile Duct Neoplasms/pathology , Neoplasm Staging
20.
Gastrointest Endosc ; 99(4): 566-576.e8, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37866710

ABSTRACT

BACKGROUND AND AIMS: Adequate preoperative biliary drainage (PBD) is recommended in most patients with resectable perihilar cholangiocarcinoma (pCCA). Most expert centers use endoscopic plastic stents rather than self-expandable metal stents (SEMSs). In the palliative setting, however, use of SEMSs has shown longer patency and superior survival. The aim of this retrospective study was to compare stent dysfunction of SEMSs versus plastic stents for PBD in resectable pCCA patients. METHODS: In this multicenter international retrospective cohort study, patients with potentially resectable pCCAs who underwent initial endoscopic PBD from 2010 to 2020 were included. Stent failure was a composite end point of cholangitis or reintervention due to adverse events or insufficient PBD. Other adverse events, surgical outcomes, and survival were recorded. Propensity score matching (PSM) was performed on several baseline characteristics. RESULTS: A total of 474 patients had successful stent placement, of whom 61 received SEMSs and 413 plastic stents. PSM (1:1) resulted in 2 groups of 59 patients each. Stent failure occurred significantly less in the SEMSs group (31% vs 64%; P < .001). Besides less cholangitis after SEMSs placement (15% vs 31%; P = .012), other PBD-related adverse events did not differ. The number of patients undergoing surgical resection was not significantly different (46% vs 49%; P = .71). Complete intraoperative SEMSs removal was successful and without adverse events in all patients. CONCLUSIONS: Stent failure was lower in patients with SEMSs as PBD compared with plastic stents in patients with resectable pCCA. Removal during surgery was quite feasible. Surgical outcomes were similar.


Subject(s)
Bile Duct Neoplasms , Cholangiocarcinoma , Cholangitis , Cholestasis , Klatskin Tumor , Self Expandable Metallic Stents , Humans , Retrospective Studies , Klatskin Tumor/surgery , Klatskin Tumor/etiology , Stents/adverse effects , Self Expandable Metallic Stents/adverse effects , Cholangiocarcinoma/surgery , Cholangiopancreatography, Endoscopic Retrograde , Drainage/methods , Cholangitis/etiology , Bile Duct Neoplasms/surgery , Bile Ducts, Intrahepatic , Cholestasis/etiology , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...